Investigation of indoor air quality in university libraries in terms of gaseous and particulate pollutants in Bartin, Turkey

dc.contributor.authorGüneş, Gülten
dc.contributor.authorYalcin, Nesibe
dc.contributor.authorÇolaklar, Huriye
dc.contributor.authorÇolaklar, Huriye
dc.contributor.authorGüneş, Gülten
dc.date.accessioned2025-10-18T13:22:25Z
dc.date.created2022
dc.date.issued2022
dc.departmentFakülteler, Mühendislik Mimarlık ve Tasarım Fakültesi, Çevre Mühendisliği Bölümü
dc.departmentFakülteler, İnsan ve Toplum Bilimleri Fakültesi, Bilgi ve Belge Yönetimi Bölümü
dc.description.abstractIndoor air quality (IAQ) was investigated in two libraries of Bartin University. Particle matter, TVOC, and CH2O were measured simultaneously in different rooms of the libraries. Measurements were made by PCE-RCM 11 measuring device. They were conducted monthly between September 2019 and October 2020 for 2 weeks for each library. TVOC mean concentration was higher than the limit value reported by Seifert et al. (1999). PM2.5 and PM10 concentrations were higher in winter unlike TVOC and CH2O concentrations. The indoor seconder blowing dust was detected to be the most important source of particulate matter in the indoor environment. On the other hand, it was thought that the pollutants in the gas phase were affected by indoor and outdoor air temperature, indoor/outdoor air exchange rate, and indoor/outdoor pollutant sources. The parameters changed during the day and in different rooms of the libraries. Pollutants did not pose any hazard on human health, since the calculated HQ and HI <= 1 for both exposure groups. The indoor air of the libraries was detected to be slightly polluted and bad according to the IAQI and IEI, respectively. On the other hand, the indoor air quality of the libraries was good in terms of all parameters according to the IAQC.
dc.description.sponsorshipBartin University Scientific Research Projects Coordination Unit [2019-FEN-A-018]
dc.description.sponsorshipThis research was funded by Bartin University Scientific Research Projects Coordination Unit (Project No.: 2019-FEN-A-018).
dc.identifier.doi10.1007/s10661-022-09818-8
dc.identifier.issn0167-6369
dc.identifier.issn1573-2959
dc.identifier.issue3
dc.identifier.orcidYalcin, Nesibe/0000-0003-0324-9111
dc.identifier.orcidGunes, Gulten/0000-0002-1760-2695
dc.identifier.pmid35182210
dc.identifier.scopus2-s2.0-85124919109
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.1007/s10661-022-09818-8
dc.identifier.urihttps://hdl.handle.net/11772/22328
dc.identifier.volume194
dc.identifier.wosWOS:000757933800001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofEnvironmental Monitoring and Assessment
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.relation.sdgGoal-03: Good Health and Well-Being
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzWoS_20251016
dc.subjectIndoor Air Quality
dc.subjectTotal Volatile Organic Compounds
dc.subjectFormaldehyde
dc.subjectHealth Risks
dc.titleInvestigation of indoor air quality in university libraries in terms of gaseous and particulate pollutants in Bartin, Turkey