Experimental analysis of cooling and heating performance of serial and parallel connected counter-flow Ranquee-Hilsch vortex tube systems using carbon dioxide as a working fluid

dc.contributor.authorKaya, Hüseyin
dc.contributor.authorUluer, Onuralp
dc.contributor.authorKocaoglu, Evren
dc.contributor.authorKırmacı, Volkan
dc.contributor.authorKırmacı, Volkan
dc.contributor.authorKaya, Hüseyin
dc.date.accessioned2025-10-18T10:11:12Z
dc.date.created2019
dc.date.issued2019
dc.departmentFakülteler, Mühendislik Mimarlık ve Tasarım Fakültesi, Makine Mühendisliği Bölümü
dc.description.abstractThis study examines the performance analysis of two counter flow Ranquee-Hilsch Vortex Tubes (RHVT) having the same geometrical properties in the condition of serial and parallel connection. The performance of CO2 as a working fluid in the vortex tube by using nozzles having 2,4 and 6 orifices, which were manufactured from polyamide and brass material has been experimentally investigated. Experimental studies were carried out by compressing CO2 through the compressor to the vortex tube at pressures between 150 and 550 kPa. The most important physical property of a RHVT is the ratio of L/D which is equal to 14 in this study. In addition, by using the data obtained from experimental results, the second law efficiency was calculated for different working conditions of the systems by exergy analysis. The highest overall temperature difference (Delta T) was obtained as 76.9 K when using parallel connected RHVT system with brass-six nozzle. (C) 2019 Elsevier Ltd and IIR. All rights reserved.
dc.identifier.doi10.1016/j.ijrefrig.2019.07.004
dc.identifier.endpage307
dc.identifier.issn0140-7007
dc.identifier.issn1879-2081
dc.identifier.orcidKaya, Huseyin/0000-0003-0575-0161;
dc.identifier.scopus2-s2.0-85070502758
dc.identifier.scopusqualityQ1
dc.identifier.startpage297
dc.identifier.urihttps://doi.org/10.1016/j.ijrefrig.2019.07.004
dc.identifier.urihttps://hdl.handle.net/11772/22251
dc.identifier.volume106
dc.identifier.wosWOS:000489835600029
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier Sci Ltd
dc.relation.ispartofInternational Journal of Refrigeration-Revue Internationale Du Froid
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzWoS_20251016
dc.subjectRanque-Hilsch Vortex Tube
dc.subjectCo2
dc.subjectCooling
dc.subjectHeating
dc.subjectExergy
dc.titleExperimental analysis of cooling and heating performance of serial and parallel connected counter-flow Ranquee-Hilsch vortex tube systems using carbon dioxide as a working fluid
dc.typeArticle
dspace.entity.typePublication
relation.isAuthorOfPublication1427e853-9cde-4054-a27a-b06f10acc59f
relation.isAuthorOfPublication454f9aac-f929-4fe1-ae43-f864695b857d
relation.isAuthorOfPublication.latestForDiscovery1427e853-9cde-4054-a27a-b06f10acc59f

Dosyalar