Investigation of strengthened low slenderness RC column by using textile reinforced mortar strip under axial load

dc.contributor.authorMercimek, Omer
dc.contributor.authorGhoroubi, Rahim
dc.contributor.authorOzdemir, Anil
dc.contributor.authorAnil, Ozgur
dc.contributor.authorErbaş, Yaşar
dc.contributor.authorErbaş, Yaşar
dc.date.accessioned2025-10-18T10:11:13Z
dc.date.created2022
dc.date.issued2022
dc.departmentFakülteler, Mühendislik Mimarlık ve Tasarım Fakültesi, İnşaat Mühendisliği Bölümü
dc.description.abstractAn experimental and numerical study was conducted to improve the critical performance of low slenderness reinforced concrete columns, such as ultimate load capacity, initial stiffness, and energy dissipation capacity, using Textile-Reinforced Mortar (TRM) strip. A total of 17 reinforced concrete columns were fabricated and tested under uni-axial compression. The effect of carbon textile type, strip width and distance, usage of carbon fiber reinforced polymer (CFRP) fan type anchors was investigated. The experimental part of the study indicated that the ultimate load capacities of reinforced concrete columns strengthened with TRM strips was increased to 1.19-1.78 times. Their initial stiffness increased to 1.01-1.99 times, and energy dissipation capacity values increased to 1.22 and 2.09 times. In addition, simulation models for the experimental specimens were created with the ABAQUS finite element software. Then the results of analyses and the experimental outputs were compared together and interpreted. Finally, using the verified FEM model, a parametric numerical study was carried out to determine the effect of the increase in the concrete compressive strength of the column on the performance of the specimens examined within the scope of the study. According to the main findings of this study, it was demonstrated that the application of the proposed TRM strips for strengthening reinforced concrete columns was a successful method.
dc.identifier.doi10.1016/j.engstruct.2022.114191
dc.identifier.issn0141-0296
dc.identifier.issn1873-7323
dc.identifier.orcidErbas, Yasar/0000-0002-3475-9678
dc.identifier.orcidOZDEMIR, ANIL/0000-0001-6563-5144
dc.identifier.scopus2-s2.0-85127112269
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.engstruct.2022.114191
dc.identifier.urihttps://hdl.handle.net/11772/22255
dc.identifier.volume259
dc.identifier.wosWOS:000792410000001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier Sci Ltd
dc.relation.ispartofEngineering Structures
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzWoS_20251016
dc.subjectRc Column
dc.subjectTrm
dc.subjectStrengthening
dc.subjectAxial Load
dc.subjectAnchor
dc.titleInvestigation of strengthened low slenderness RC column by using textile reinforced mortar strip under axial load
dc.typeArticle
dspace.entity.typePublication
relation.isAuthorOfPublication63ffb47f-2aac-44cd-850c-eb2305f7c20e
relation.isAuthorOfPublication.latestForDiscovery63ffb47f-2aac-44cd-850c-eb2305f7c20e

Dosyalar