Exergy analysis and performance of a counter flow Ranque-Hilsch vortex tube having various nozzle numbers at different inlet pressures of oxygen and air

dc.contributor.authorKırmacı, Volkan
dc.contributor.authorKırmacı, Volkan
dc.date.accessioned2025-10-18T10:11:12Z
dc.date.created2009
dc.date.issued2009
dc.departmentFakülteler, Mühendislik Mimarlık ve Tasarım Fakültesi, Makine Mühendisliği Bölümü
dc.description.abstractAn experimental investigation is made to determine the effects of the orifice nozzle number and the inlet pressure on the heating and cooling performance of the counter flow Ranque-Hilsch vortex tube when air and oxygen used as a fluid. The orifices used at these experiments are made of the polyamide plastic material. The thermal conductivity of polyamide plastic material is 0.25 W/m degrees C. Five orifices with nozzle numbers of 2, 3, 4,5 and 6 have been manufactured and used during the experiments. For each one of the orifices (nozzle numbers) when used with two different fluids, inlet pressures were adjusted from 150 kPa to 700 kPa with 50 kPa increments, and the exergy efficiency was determined. During the experiments, a vortex tube is used with an L/D ratio of is, and cold mass fraction is held constant at 0.5. As a result of the experimental study, it is determined that the temperature gradient between the hot and cold fluid is decreased with increasing of the orifice nozzle number. (C) 2009 Elsevier Ltd and IIR. All rights reserved.
dc.identifier.doi10.1016/j.ijrefrig.2009.04.007
dc.identifier.endpage1633
dc.identifier.issn0140-7007
dc.identifier.issn1879-2081
dc.identifier.issue7
dc.identifier.orcidKIRMACI, Volkan/0000-0001-7076-1911;
dc.identifier.scopus2-s2.0-69749104076
dc.identifier.scopusqualityQ1
dc.identifier.startpage1626
dc.identifier.urihttps://doi.org/10.1016/j.ijrefrig.2009.04.007
dc.identifier.urihttps://hdl.handle.net/11772/22244
dc.identifier.volume32
dc.identifier.wosWOS:000271336800014
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier Sci Ltd
dc.relation.ispartofInternational Journal of Refrigeration-Revue Internationale Du Froid
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzWoS_20251016
dc.subjectRefrigeration System
dc.subjectVortex Tube
dc.subjectRanque Hilsch
dc.subjectExperiment
dc.subjectNozzle
dc.subjectEfficiency
dc.subjectExergy