An Ultrasound Array of Emitter-Receiver Stacks for Microbubble-Based Therapy

Yükleniyor...
Küçük Resim

Tarih

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

IEEE-Inst Electrical Electronics Engineers Inc

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Araştırma projeleri

Organizasyon Birimleri

Öğe Türü: Organizasyon Birimi ,
Mühendislik Mimarlık ve Tasarım Fakültesi, Elektrik-Elektronik Mühendisliği Bölümü
Bartın Üniversitesi Mühendislik Fakültesi Elektrik-Elektronik Mühendisliği Bölümü, 2008 yılında kurulmuştur. Şu anda eğitime Mühendislik, Mimarlık ve Tasarım Fakültesi altında devam edilmektedir. Bölümde, Devreler ve Sistemler, Elektromanyetik Alanlar ve Mikrodalga Teorisi, Elektrik Makinaları, Elektrik Tesisleri, Elektronik, Haberleşme ve Kontrol ve Kumanda Sistemleri olmak üzere 7 Anabilim Dalı bulunmaktadır.

Dergi sayısı

Özet

Most therapeutic ultrasound devices place emitters and receivers in separate locations, so that the long therapeutic pulses (>1 ms) can be emitted while receivers monitor the procedure. However, with such placement, emitters and receivers are competing for the same space, producing a trade-off between emission efficiency and reception sensitivity. Taking advantage of recent studies demonstrating that short-pulse ultrasound can be used therapeutically, we aimed to develop a device that overcomes such trade-offs. The array was composed of emitter-receiver stacks, which enabled both emission and reception from the same location. Each element was made of a lead zirconate titanate (PZT)-polyvinylidene fluoride (PVDF) stack. The PZT (frequency: 500 kHz, diameter: 16 mm) was used for emission and the PVDF (thickness: 28 mu m, diameter: 16 mm) for broadband reception. 32 elements were assembled in a 3D-printed dome-shaped frame (focal length: 150 mm; ff -number: 1) and was tested in free-field and through an ex-vivo human skull. In free-field, the array had a 4.5 x 4.5 x 32 mm focus and produced a peak-negative pressure (PNP) of 2.12 MPa at its geometric center. The electronic steering range was +/- 15 mm laterally and larger than +/- 15 mm axially. Through the skull, the array produced a PNP of 0.63 MPa. The PVDF elements were able to localize broadband microbubble emissions across the skull. We built the first multi-element array for short-pulse and microbubble-based therapeutic applications. Stacked arrays overcome traditional trade-offs between the transmission and reception quality and have the potential to create a step change in treatment safety and efficacy.

Açıklama

Anahtar Kelimeler

Ultrasound Array, Stacked Transducer, Ultrasound Therapy, Microbubbles

Kaynak

Ieee Transactions on Biomedical Engineering

WoS Q Değeri

Scopus Q Değeri

SDG

Cilt

71

Sayı

2

Künye

Onay

İnceleme

Ekleyen

Referans Veren