How to prepare head tissue-equivalent liquids for SAR calculations, dosimetry and hyperthermia researches at 900 and 1800 MHz GSM frequencies

dc.contributor.authorSorgucu, Ugur
dc.contributor.authorDeveli, Ibrahim
dc.contributor.authorOzen, Sukru
dc.date.accessioned2025-10-18T10:11:15Z
dc.date.created2016
dc.date.issued2016
dc.departmentBartın Üniversitesi
dc.description.abstractThe potential harmful effect of electromagnetic fields on human health is an important issue that has been widely discussed in the scientific community. The investigation of temperature rise in human body following exposure to electromagnetic fields has been found impractical in many aspects. Therefore, fabrication of the tissue-equivalent liquids (TELs) is required. TELs have been widely employed in specific absorption rate calculations, dosimetry and hyperthermia researches. In this study, two separate head tissue-equivalent liquids (HELs) were prepared for 900 and 1800 MHz frequencies. The conductivity and relative permittivity of the HEL prepared for 900 MHz frequency were found to deviate from The Institute of Electrical and Electronics Engineers (IEEE) standards at the rates of 6.20 and 2.70 %, whereas the HEL prepared for 1800 MHz applications exhibited 1.83 and 3.22 % deviations from IEEE standards, respectively. This study provides a method for researchers to prepare their own HELs in a practical way.
dc.description.sponsorshipErciyes University of Turkey [FDK 2013-4576]
dc.description.sponsorshipThis work was supported by the research fund from the Erciyes University of Turkey (grant number: FDK 2013-4576).
dc.identifier.doi10.1093/rpd/ncv351
dc.identifier.endpage373
dc.identifier.issn0144-8420
dc.identifier.issn1742-3406
dc.identifier.issue3
dc.identifier.orciddeveli, ibrahim/0000-0001-5878-677X
dc.identifier.orcid, sukru/0000-0002-5538-6786
dc.identifier.orcidsorgucu, ugur/0000-0001-9227-1526;
dc.identifier.pmid26116300
dc.identifier.scopus2-s2.0-84959876406
dc.identifier.scopusqualityQ3
dc.identifier.startpage365
dc.identifier.urihttps://doi.org/10.1093/rpd/ncv351
dc.identifier.urihttps://hdl.handle.net/11772/22275
dc.identifier.volume168
dc.identifier.wosWOS:000371608200010
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherOxford Univ Press
dc.relation.ispartofRadiation Protection Dosimetry
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzWoS_20251016
dc.subjectDielectric-Properties
dc.subjectBrain-Tissue
dc.subjectEnergy-Absorption
dc.subjectDependence
dc.subjectPhantom
dc.subjectRadiation
dc.subjectValues
dc.subjectRange
dc.titleHow to prepare head tissue-equivalent liquids for SAR calculations, dosimetry and hyperthermia researches at 900 and 1800 MHz GSM frequencies