ENERGY AND EXERGY ANALYSIS OF A NOVEL THREE-STAGE HEAT PUMP DRYING SYSTEM
Yükleniyor...
Tarih
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Bartın Üniversitesi
Erişim Hakkı
info:eu-repo/semantics/openAccess
Özet
A three-stage heat pump dryer is analyzed and assessed in terms of energy and exergy performances using different refrigerants such as R134-a, R12, and R22. Many parametric optimization studies are applied for the corresponding system in order to specify the best performing system and environmental parameters. R12 shows the highest energy and exergy efficiencies while requirement of compressor work is low when R12 is used as a refrigerant. The system is not much influenced from the environmental conditions. In addition, the overall system energy and exergy efficiencies are 44.23% and 55.7% for R134-a, respectively.
Açıklama
Anahtar Kelimeler
Mechanical Engineering, Makine Mühendisliği
Kaynak
Bartın University International Journal of Natural and Applied Sciences
WoS Q Değeri
Scopus Q Değeri
SDG
Cilt
2
Sayı
1