Comparison of phenol removal with ozonation in jet loop reactor and bubble column

dc.contributor.authorBarlak, Melahat Semin
dc.contributor.authorDegermenci, Nejdet
dc.contributor.authorCengiz, Ibrahim
dc.contributor.authorÖzel, Handan Ucun
dc.contributor.authorYildiz, Ergun
dc.contributor.authorÖzel, Handan Ucun
dc.date.accessioned2025-10-18T09:58:25Z
dc.date.created2020
dc.date.issued2020
dc.departmentFakülteler, Orman Fakültesi, Orman Endüstri Mühendisliği Bölümü
dc.description.abstractThis study aimed to remove phenol with ozonation in a jet loop reactor (JLR) and a bubble column (BC). In the first stage of the study, the mass transfer properties of JLR were determined and superiority over BC reactors were shown, and in the second stage, these reactors were used in phenol removal studies. At the same conditions, the volumetric mass transfer coefficient of JLR was 0.540 min-1, while this value was determined as 0.246 min(-1) in the BC reactor. In phenol removal, the effects of initial phenol concentration, ozone dosage and pH on phenol and chemical oxygen demand (COD) removal were determined for both JLR and BC. While the pseudo-first rate constant for phenol removal in JLR at 221 mg/min ozone dosage was 0.1756 min(-1), this value was only calculated as 0.1157 min(-1) in the BC reactor. As a result, it has been shown that JLRs can achieve higher ozone gas transfer with lower energy consumption and perform more effective phenol and COD removal than BC reactors, especially at low pH and high ozone dosages.
dc.description.sponsorshipScientific and Technological Research Council of Turkey [107Y298]
dc.description.sponsorshipThe authors are grateful for the financial support provided by the Scientific and Technological Research Council of Turkey (TUB.ITAKProject No: 107Y298).
dc.identifier.doi10.1016/j.jece.2020.104402
dc.identifier.issn2213-2929
dc.identifier.issn2213-3437
dc.identifier.issue5
dc.identifier.orcidDegermenci, Nejdet/0000-0003-3135-1471
dc.identifier.orcidÖzel, Handan Ucun/0000-0003-1293-0945
dc.identifier.orcidCENGIZ, IBRAHIM/0000-0003-3171-6629
dc.identifier.scopus2-s2.0-85092698443
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.jece.2020.104402
dc.identifier.urihttps://hdl.handle.net/11772/19677
dc.identifier.volume8
dc.identifier.wosWOS:000575524900009
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier Sci Ltd
dc.relation.ispartofJournal of Environmental Chemical Engineering
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzWoS_20251016
dc.subjectOzonation
dc.subjectJet Loop Reactor
dc.subjectBubble Column
dc.subjectPhenol
dc.subjectChemical Oxygen Demand
dc.titleComparison of phenol removal with ozonation in jet loop reactor and bubble column
dc.typeArticle
dspace.entity.typePublication
relation.isAuthorOfPublication985c8944-4c5c-4194-98da-fd4ce843d343
relation.isAuthorOfPublication.latestForDiscovery985c8944-4c5c-4194-98da-fd4ce843d343

Dosyalar