WATER DISINFECTION WITH ADVANCED METHODS: SUCCESSIVE AND HYBRID APPLICATION OF ANTIBACTERIAL COLUMN WITH SILVER, ULTRASOUND AND UV RADIATION

dc.contributor.authorGemici, B. T.
dc.contributor.authorKarel, F. B.
dc.contributor.authorKaraer, F.
dc.contributor.authorKoparal, A. S.
dc.contributor.authorGemici, Betül Tuba
dc.date.accessioned2025-10-18T10:05:27Z
dc.date.created2018
dc.date.issued2018
dc.departmentBartın Üniversitesi
dc.description.abstractThe disinfection process is of great importance to the water supply to prevent diseases spread by water. Due to its negative impacts on human health, the number of studies conducted on disinfection systems alternative to chlorination and similar traditional methods has been increased. Successive and hybrid systems that are highly efficient in inactivating the pathogenic microorganisms that may be present in water are being developed. In this study, the disinfection efficiency of the antibacterial filled column, ultrasonic reactor and UV reactor that we developed was increased by the successive and hybrid usage of the methods when Escherichia coli bacteria were used to detect the disinfection efficiency of the systems. In single disinfection studies, bacterial inactivation efficiency occurred in UV process was higher than antibacterial column and also, efficiency occurred in antibacterial column was higher than ultrasonic reactor. Triple hybrid usage of these systems resulted in an 8 log microbial inactivation reducing single treatment disadvantages of these systems. Furthermore, the flow speed and temperature effect were examined during the studies, and it was observed that the temperature had a positive effect on the hybrid system.
dc.description.sponsorshipTUBITAK [108Y019]
dc.description.sponsorshipThis study was supported within the scope of the TUBITAK Project No 108Y019 under the title of Application of Hybrid Water Disinfection System Application with Nano technologic Material Additive.
dc.identifier.doi10.15666/aeer/1604_46674680
dc.identifier.endpage4680
dc.identifier.issn1589-1623
dc.identifier.issn1785-0037
dc.identifier.issue4
dc.identifier.orcidKoparal, Ali Savas/0000-0002-6894-5604
dc.identifier.orcidKARAER OZMEN, FADIME/0000-0003-4423-205X
dc.identifier.scopus2-s2.0-85052102868
dc.identifier.scopusqualityQ3
dc.identifier.startpage4667
dc.identifier.urihttps://doi.org/10.15666/aeer/1604_46674680
dc.identifier.urihttps://hdl.handle.net/11772/21258
dc.identifier.volume16
dc.identifier.wosWOS:000441908200063
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherCorvinus Univ Budapest
dc.relation.ispartofApplied Ecology and Environmental Research
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.relation.sdgGoal-03: Good Health and Well-Being
dc.relation.sdgGoal-06: Clean Water And Sanitation
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzWoS_20251016
dc.subjectBacterial Inactivation
dc.subjectUltrasound
dc.subjectSilver
dc.subjectUltraviolet Radiation
dc.titleWATER DISINFECTION WITH ADVANCED METHODS: SUCCESSIVE AND HYBRID APPLICATION OF ANTIBACTERIAL COLUMN WITH SILVER, ULTRASOUND AND UV RADIATION
dc.typeArticle
dspace.entity.typePublication
relation.isAuthorOfPublicationfa26f73d-ba2f-4271-93ba-197e4b0627e1
relation.isAuthorOfPublication.latestForDiscoveryfa26f73d-ba2f-4271-93ba-197e4b0627e1

Dosyalar