Earthquake performance of the two approach viaducts of the bosphorus suspension bridge

dc.contributor.authorBaş, Selçuk
dc.contributor.authorApaydin, Nurdan Memisoglu
dc.contributor.authorCelep, Zekai
dc.contributor.authorBaş, Selçuk
dc.date.accessioned2025-10-18T10:02:52Z
dc.date.created2016
dc.date.issued2016
dc.departmentFakülteler, Mühendislik Mimarlık ve Tasarım Fakültesi, İnşaat Mühendisliği Bölümü
dc.description.abstractThe main purpose of this paper is to determine the dynamic characteristics and the structural stability of the two approach viaducts of the Bosphorus Suspension Bridge under the expected stresses that would be caused during earthquake conditions. The Ortakoy and the Beylerbeyi approach viaducts constitute the side spans of the bridge at two locations. The bridge's main span over the Bosphorus is suspended, whereas they are supported at the base at either end. For the numerical investigation of the viaducts, 3-D computational structural finite element-FE models were developed. Their natural frequencies and the corresponding mode shapes were obtained, analyzed, presented and compared. The performances of the viaducts, under earthquake conditions, were studied considering the P-Delta effects implementing the push-over (POA) and the non-linear time-history analyses (NTHA). For the NTHA, three earthquake ground motions were generated depending on the location of the bridge. Seismic performances of the viaducts were determined in accordance with the requirements of the Turkish Seismic Code for the Earthquake Design of Railways Bridges (TSC-R/2008) and those of Caltrans (CALTRANS-2001) given for Seismic Design of Steel Bridges, separately. Furthermore, the investigation was extended for evaluating the possible need for retrofitting in the future. After the analysis of the resultant data, a retrofit recommendation for the viaducts was presented.
dc.identifier.doi10.12989/eas.2016.11.3.387
dc.identifier.endpage406
dc.identifier.issn2092-7614
dc.identifier.issn2092-7622
dc.identifier.issue3
dc.identifier.orcidMEMISOGLU APAYDIN, NURDAN/0000-0002-3563-2580
dc.identifier.orcidCelep, Zekai/0000-0002-5246-9818;
dc.identifier.scopus2-s2.0-84991761857
dc.identifier.scopusqualityQ2
dc.identifier.startpage387
dc.identifier.urihttps://doi.org/10.12989/eas.2016.11.3.387
dc.identifier.urihttps://hdl.handle.net/11772/20792
dc.identifier.volume11
dc.identifier.wosWOS:000384816100001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherTechno-Press
dc.relation.ispartofEarthquakes and Structures
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzWoS_20251016
dc.subjectSuspension Bridge
dc.subjectApproach Viaducts
dc.subjectSeismic Performance
dc.subjectNon-Linear Time-History
dc.subjectPush-Over
dc.subjectSeismic Retrofit
dc.titleEarthquake performance of the two approach viaducts of the bosphorus suspension bridge