IS THERE ANY EFFECT OF NON-SUITABLE PULL TECHNIQUE IN BACK & LEG DYNAMOMETERS ON THE LEG STRENGTH TEST RESULTS?

dc.contributor.authorEyuboglu, Ender
dc.contributor.authorAslan, Cem Sinan
dc.contributor.authorKarakulak, Izzet
dc.contributor.authorSahin, Fatma Nese
dc.contributor.authorEyuboğlu, Ender
dc.date.accessioned2025-10-18T13:23:16Z
dc.date.created2019
dc.date.issued2019
dc.departmentBartın Üniversitesi
dc.description.abstractIntroduction: Dynamometers are valid and reliable test instruments that have been used for many years to measure strength. However, there are excessive differences in leg strength scores in different studies with similar groups. This situation suggests a non-conformity to testing procedures occurred during the practice of the tests. The purpose of this study was to determine the effect of non-suitable pulling technique on the leg strength test results. Materials and methods: A total of 127 healthy subjects (24 female athletes and 41 male athletes, 22 sedentary females and 40 sedentary males) were included in the study. A back & leg Dynamometer was used to determine the leg strength of the participants. The participants pulled up the dynamometer's grab handle with and without contact with their upper leg. Results: The results showed that there was a significant difference (p=0.000) between contacted and non-contact pulling trials of all participants. The percentage difference of leg strength between contacted and non-contact pull was 51.69% (43.25 kg) for female athletes, 54.78 (73.46 kg) for male athletes, 5631% (37.52 kg) for sedentary females, and 50.69% (65.55 kg) for sedentary males. Conclusion: There were significant differences between contacted and non-contact pull trials. It was determined that during the pulling phase if the dynamometer's grab-handle contacted the upper leg of a subject, the strength measurement's score increased considerably. In this case, it can be said that non-suitable pulling technique in the back & leg dynamometers affects the leg strength test scores.
dc.identifier.doi10.19193/0393-6384_2019_3_211
dc.identifier.endpage1377
dc.identifier.issn0393-6384
dc.identifier.issn2283-9720
dc.identifier.issue3
dc.identifier.orcidKarakulak, Izzet/0000-0003-0673-4796
dc.identifier.orcidASLAN, CEM SINAN/0000-0002-0369-7240
dc.identifier.orcidSAHIN, FATMA NESE/0000-0002-8777-5807;
dc.identifier.scopus2-s2.0-85066049540
dc.identifier.scopusqualityQ2
dc.identifier.startpage1373
dc.identifier.urihttps://doi.org/10.19193/0393-6384_2019_3_211
dc.identifier.urihttps://hdl.handle.net/11772/22791
dc.identifier.volume35
dc.identifier.wosWOS:000470923400029
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherCarbone Editore
dc.relation.ispartofActa Medica Mediterranea
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzWoS_20251016
dc.subjectBack & Leg Dynamometer
dc.subjectLeg Contact
dc.subjectReliability Of Measurement
dc.titleIS THERE ANY EFFECT OF NON-SUITABLE PULL TECHNIQUE IN BACK & LEG DYNAMOMETERS ON THE LEG STRENGTH TEST RESULTS?