Evidence-based seismic performance assessment of non-structural components in fixed-base and base-isolated hospital buildings using monitoring data

Yükleniyor...
Küçük Resim

Tarih

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Springer

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Araştırma projeleri

Organizasyon Birimleri

Öğe Türü: Organizasyon Birimi ,
Mühendislik Mimarlık ve Tasarım Fakültesi, İnşaat Mühendisliği Bölümü
Temel mühendislik alanlarından biri olan İnşaat Mühendisliği; toplumun yaşam kalitesinin gelişiminde, Hayatın her kesiminde ihtiyaç duyulan yapıların tasarım ve yapımında aktif rol almaktadır. Yaşanan gelişmeler, güvenli yapıların tasarım ve yapımında inşaat mühendisliğinin ve bu alanda yetişmiş iş gücünün önemini ortaya koymaktadır.

Dergi sayısı

Özet

Hospitals are critical facilities that must remain operational during and after earthquakes. However, the seismic vulnerability of non-structural hospital components (NSCs), which often determines post-earthquake functionality, is usually estimated using analytical or code-based demand models rather than quantified using observed earthquake data. This study presents a quantifiable, evidence-based assessment of the real earthquake performance of fixed-base and base-isolated hospital buildings using monitoring data. A representative set of hospital buildings in California was examined, including both isolated and non-isolated configurations with different isolation systems and site conditions. Multi-site strong-motion records were analyzed to evaluate ground- and floor-level accelerations, displacements, inter-story drift ratios (IDRs), fundamental periods and response spectral characteristics over a range of seismic intensities. The measured demands were then directly compared with the established acceleration- and drift-based NSC damage thresholds, as well as the roof-level design response spectra. The results show that fixed-base hospitals often exceed critical NSC thresholds due to significant roof acceleration amplification, high IDRs and substantial high-frequency transmission. In contrast, base-isolated hospitals consistently maintain floor accelerations and IDRs below critical NSC limits, demonstrating effective low-pass filtering and reduced exceedance potential.

Açıklama

Anahtar Kelimeler

Hospital Buildings, Base-Isolated Buildings, Fixed-Base Buildings, Nonstructural Component, Seismic Performance, Structural Health Monitoring, Inter-Story Drift Ratio, Floor Response Spectra, Healthcare Infrastructure

Kaynak

Bulletin of Earthquake Engineering

WoS Q Değeri

Scopus Q Değeri

SDG

Cilt

24

Sayı

6

Künye

Onay

İnceleme

Ekleyen

Referans Veren