Modelling of degraded power MOSFET effects on inverter static parameters

Yükleniyor...
Küçük Resim

Tarih

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Elsevier

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Araştırma projeleri

Organizasyon Birimleri

Dergi sayısı

Özet

In this study, electrical constant stress method which is one of accelerated tests is applied to power vertical double diffused MOSFETs continued up to 6 hours. The stress induced changes of characteristic parameters (threshold voltage, mobility, etc.) of power MOSFETs are extracted. A resistive load NMOS inverter is set up and degraded power MOSFET effects on its static parameters are investigated experimentally. Besides the obtained experimental results, a simple circuit model is proposed to simulate the stress induced changes in NMOS inverter static parameters. In this manner, obtained experimental results are supported by simulation study. Proposed degradation model has ability to help designers to predict circuit reliability in the early stages of design. (C) 2015 Elsevier Ltd. All rights reserved. Selection and Peer-review under responsibility of Conference Committee Members of International Semiconductor Science and Technology Conference 2015 (ISSTC 2015).

Açıklama

International Semiconductor Science and Technology Conference (ISSTC) -- MAY 11-13, 2015 -- Kusadasi, TURKEY

Anahtar Kelimeler

Constant Electrical Stress, Static Parameters Of Nmos Inverter, Degradation Modelling

Kaynak

Materials Today-Proceedings

WoS Q Değeri

Scopus Q Değeri

SDG

Cilt

3

Sayı

5

Künye

Onay

İnceleme

Ekleyen

Referans Veren